希捷企業盤恢復成功
瀏覽量: 次 發布日期:2019-02-14 22:38:47
服務器型號:lenovo thinkserver rd630 ,4塊2t 希捷企業
恢復結果:經檢測2號及3號硬盤報錯損壞,經檢測3號盤為最后損壞硬盤,經檢測該盤固件損壞,有大量壞道,兆柏科技通過pc3000 修復固件后,硬盤正常鏡像,通過鏡像盤數據恢復成功,客戶用友erp正常導出,數據遷移到新硬盤后數據恢復成功。

3 T>
Prod Desc: Megalodon LuxorPlus2.0/Dillon, SP 2.2, NVC, Buffer ECC
Package Version: MGD38B.SDN1.BF015B.SN03
Serial #: Z1X1BX5M
Changelist: 00583874
Model #: ST2000NM0033
ID: 110
ASCII Diag mode
F3 T>
Megalodon LuxorPlus2.0/Dillon, SP 2.2, NVC, Buffer ECC
Product FamilyId: 63, MemberId: 06
HDA SN: Z1XXXXX, RPM: 7202, Wedges: 1A0, Heads: 5, OrigHeads: A, Lbas: 0000E9163043, PreampType: CC 06
Bits/Symbol: C, Symbols/UserSector: 197, Symbols/SystemSector: 195
PCBA SN: 0000C416B0TD, Controller: LUXORLPLUS_2_0( 203)(FF-FF-FF-F, Channel: STX_DUNRAVEN, PowerAsic: Unknown Rev 00, BufferBytes: 8000000
Package Version: MGD38B.SDN1.BF015B.SN03 , Package P/N: 100732531, Package Global ID: 00493162,
Package Build Date: 07/05/2013, Package Build Time: 09:17:18, Package CFW Version: MGD3.SDN1.00583874.00493162,
越來越多的希捷硬盤存在固件鎖的問題。所謂的固件鎖就是硬盤可以進入T級,但是只能執行少數查看信息的指令,無法執行關鍵性的操作類終端指令。在這種情況下,我們無法執行寫入和修改指令,并且在嘗試執行終端指令時,會返回“Diagnostic Port Locked”的提示。凡是看到這個提示,就可以確認存在固件鎖。